Software Update Name: BCM450.R100.SU.System-004.200903

Applicable H/W Platforms: BCM450

Applicable S/W Platforms: 8.0.1.00, 8.0.1.05

Category: GEN

Installation Recommendations:
This update should be applied to all new installs of BCM450 Release 1.0. 
Existing installations should have this update applied if they are experiencing any 
of the issues that are corrected. There is no need to schedule specific maintenance 
to apply this upgrade if there are no reported issues. In those cases, systems should
be updated at the next regular service opportunity.

The Element Manager from this System Smart Update must be downloaded and installed for this update to have full effect.

Components & Versions:

   altroot-bins 2.0.1
   bcmEMcartridge BCM450R1.2.08
   bsp 2.0.60
   bsp-fpga-fw 2.0.1
   bsp-kernel 2.0.2.3
   core-telephony 2.0.70.02.00.5
   core-telephony-provider 2.0.319
   element-manager 2.0.300
   feps 2.0.325.5.17
   lan-provider 2.0.327.1.11
   mof-db 1.07.175.5
   recovery-config 2.0.21.2.3
   safeos-initrd 2.0.1
   scd 50.1.0.201.2.2
   software-management-provider 2.0.320
   system-release 8.0.1.05.329
   traceroute 1.4a12.3
   uboot 2.0.135.3.19
   uboot-vars 2.0.0.1
   usb-flash-content 2.0.1
   utps 2.0.328.1.7
   webpage 2.0.12

  Constituent Updates:
  ===================

  New updates for this SU:
  -------------------------
  BCM450.R100.CORE-TELEPHONY-24
  BCM450.R100.KERNEL-UBOOT-23
  BCM450.R100.FEPS-22
  
  Updates from previous SU:
  --------------------------
  BCM450.R100.DSCP-CONFIG-11  
  BCM450.R100.TRACEROUTE-10
  BCM450.R100.UTPS-7
  BCM450.R100.UBOOT-VARS-5
  BCM450.R100.SU.System-001.200810

Dependencies:
   Required Updates: None

   Product Dependencies: None

Size: 172.0 MB

Size of changed content since last Smart Update: 8 MB

System Impact:
   Time to apply approximately 10 minutes
   Does update application force reboot: Yes
   Over last Cumulative Smart Update: Yes
   Over default content:              Yes

Other Impacts: 
   All services will be unavailable during the update until the system reboot completes.

Limitations: None

Update Removable: No

Element Manager moved from Desktop SU to System SU:
-----------------------------------------------

To remove circular dependencies, the Element Manager client has been
moved from the Desktop SU to the System SU.

- BCM Element Manager installation with upgrade option selected
  If a customer's PC already has BCM Element Manager or BCM50 Element Manager installed, 
  and chooses to install Business Element Manager with upgrade function, the Windows registry 
  entry for the older BCM Element Manager and BCM50 Element Manager will remain. 
  This update fixes this issue, and ensures the older Element Manager registry entries are removed 
  properly if the upgrade function is chosen during Business Element Manager installation.
  Q01810771-01


Software Update BCM450.R100.CORE-TELEPHONY-24 Description:
----------------------------------------------------------

- System intermittently performs "cold start" 
  When making an outgoing PRI call coretel may occasionally
  crash.
  Q01949895

- Unable to apply template to sets, language error seen using English (Australian)
  In the Australian Market profile, When using the Set Templates within Element 
  Manager and the selected language is English (Australian), it fails to apply the template.
  Q01942112

- PRI doesn't come back into service after remote alarm clears
  When there is a short interruption of the PRI service that results in a remote 
  alarm (AIS, RAI), the DTM Module in the BCM shows a remote alarm 
  (yellow led in the upper left corner is lit) as expected. However, when the PRI 
  service is re-established, the DTM Module still shows a remote alarm and no
  incoming or outgoing calls are possible (Not expected) 
  Remote alarm condition should be cleared on the DTM Module.
  Q01822428-02

- IP Trunks show up in Pool A By Default
  After the IP Trunks are Deconfigured and Reconfigured under Telephony Resources
  the Active VoIP Lines show up in Line Pool A instead of Block A.
  Q01946949

- Calls get disconnected after about 30 seconds
  In Australian profile BCM connected via PRI QSIG to Nortel Passport
  4400/7480. An international call will disconnect after 31 seconds if
  it is not answered.
  Q01898555-02

- "Message for you", "line 9 called" displayed intermittently on sets
  If there is a pending voice mail message on a set ("Msg for you" on
  the display) and an outgoing call is made on line 167, once the far
  end answers the call "Msg for you", "line 9 called" will be displayed.
  Q01875614-02

- Remote MWI from CO is not lighting the message waiting lamp on BCM sets 
  When an incoming call is forwarded to the Central Office voice mail, the 
  message waiting indicator is not lit on the called BCM set after the message 
  has been left.
  Q01894588-03

- Tandem calls disconnected after placed on hold when TAT feature is enabled
   Problem: 
   - An Incoming analog line call is tandemed from one BCM to another 
     over VoIP where it is answered. 
   - The call is transferred back to the tandem BCM  where it is answered. 
     Trunk anti-tromboning takes place on answer (TAT).
   - That set which answered the call has an appearance of the incoming analog trunk. 
   - If answered call is placed on hold then picked up on another set, (transfer via
     hold) the call is cut off.
  Q01747421-04

- Getting "Not in Service" at times when using external Auto Dial Key
  Intermittently when using the external Auto Dial, a "Not In Service"
  error is returned for outgoing calls.
  Q01904250-01

- Call transfers drop at times
  The customer is getting intermittent disconnects on transferred  trunk calls
  when LAN CTE is used to connect the 2 calls together. 
  Q01933772-02

- PRI calls cutting off intermittently
  Intermittently, an incoming PRI calls may be disconnected 
  if there are 8-9 simultaneous PRI calls. Only one call at 
  a time gets disconnected and the problem happens only on
  incoming calls.
  Q01923297-01


Software Update BCM450.R100.KERNEL-UBOOT-23 Description:
--------------------------------------------------------

- Internal USB issue
  Internal USB flash drive fails to work intermittently. In order to fix the
  issue internal USB is configured to work in OHCI mode.
  This update resolves the issue.    
  Q01961959, Q01962576

- Reboot reason becomes corrupt and the system fails to boot
  Due to some reasons if the "reboot reason" becomes corrupt the BCM
  fails to boot. This update resolves the issue.
  Q01963139


Software Update BCM450.R100.FEPS-22 Description:
------------------------------------------------

- Ensure no MCDN sent out when disabled
  There is incomplete logic to disable MCDN from being sent out in a 
  SIP 183 Progress message which causes some third party interop issues.
  Q01914609-01

- Ignore SDP answer when no version increment
  Voice path problems occur when BCM attempts to treat the duplicate 
  received SDP as a new OFFER.
  Q01915068-02

- Explicit support for Silence Suppression in SIP SDP Media Attributes
  Some voice path issues are caused by different expectations of the default
  SDP Media Attributes when not specified.
  Q01925484-01

- RFC3407 Enhancement to support Simple Capability Declaration
  The inability to recognize T.38 capabilities of some third party
  switches means that the switch to T.38 FAX will not happen.
  Q01920355-01

- SIP calls not disconnecting properly
  The BCM often sends a SIP re-INVITE(inactive media) just as it is tearing
  down a call. This can cause some third party switches to leave trunks 
  tied up for up to several minutes.
  Q01938547

- No Voice Path on SIP calls to CS1K 5.5 tandem to PSTN
  A message arriving at the BCM from the CS1K arrives while in a state in which
  it is not expected, and is not properly acted on.
  Q01928517-02


Software Update BCM450.R100.DSCP-CONFIG-11 Description:
-----------------------------------------------

- User interface for configuring DiffServ Code Point (DSCP) values
  This is an enhancement which allows customers to configure or modify 
  via the user interface (Element Manager) the DSCP (TOS byte) value of 
  locally generated IP traffic in the following areas: VoIP signaling 
  traffic, VoIP voice media traffic, T.38 fax media traffic, and video 
  media traffic. The new user interface option is located under the 
  "Configuration"->"Data Services"->"QoS" menu.
  Q01904159-02

- bcmEMcartridge update caused failure to download cartridge 
  An update to the version of the Element Manager cartridge resulted
  in a failure to download the cartridge. This update resolves the
  problem.
  Q01957050

- Software Update History included with logs 
  As an aid to any future problem diagnosis, the Software Update History 
  is included when the logs are collected.
  Q01936481-04


Software Update BCM450.R100.TRACEROUTE-10 Description:
-----------------------------------------------

- traceroute utility does not work on BCM450 system.
  traceroute utility compiled in ebuild environment does not work as expected. 
  This is because ebuild does not mount proc file system before compiling
  traceroute binary. This update resolves the issue.   
  Q01946077  


Software Update BCM450.R100.UTPS-7 Description:
-----------------------------------------------

- The last "L" of the "NEWCALL" softkey is shifted to the next key
  Support has been added so that all the softkey labels which are displayed
  on 1110, 1120, 1140 IPSets are in lower case except for the first character.
  Q01930775


Software Update BCM450.R100.UBOOT-VARS-5 Description:
-----------------------------------------------

- Wrong CPU clock speed was detected after warm reset 
  System runs slower than expected (80%) after a software reboot.
  Q01912610

- Incorrect LED display after shutdown of the system
  LEDs may be incorrect on system shutdown request, identifying incorrect state
  Q01906895

- U-Boot environment variables are incorrect
  BCM450 systems contained the incorrect U-Boot environment variables, 
  resulting in outdated kernel and FPGA firmware being used.
  Q01940394
   
- ADID module is not getting enabled
  With this update the ADID will initialize, the ADID Status LEDs will  
  appear solid green and telephony services will be able to be supported 
  using the ADID. 
  Q01916769 


Software Update BCM450.R100.SU.System-001.200810 Description:
-----------------------------------------------

-  Cannot assign multiple target lines to Line 616
  If an attempt is made to configure multiple appearances of a
  target line whose number is 617 or higher, the number of
  appearances changes back to 1. For example, if target line 617
  is assigned to set 221 with 2 appearances, then when the screen
  in Element Manager is refreshed, it will show only 1 appearance.
  Q01919822

- ADID Module is not getting enabled in BCM450
  With this update the ADID will initialize, the ADID Status LEDs will
  appear sold green and telephony services will be able to be supported
  using the ADID.
  Q01916769

- SIP 503 Service Unavailable vs 480 Temporarily Unavailable
  When all VoIP trunks became busy, SIP inbound calls would be
  rejected by BCM with return code 480 Temporarily Unavailable.
  The correct return code should be 503 Service Unavailable, which
  allowed CS1000 to route the SIP calls fallback to PSTN over analog trunks.
  Q01854111-02

- User Application Webpage - Nortel VPN Client
  The BCM450 does not have a router so the VPN client has no termination
  point. The link to download the VPN client has been removed.
  Q01924189

- Call forward to DID does not work intermittently
  PRI to SIP trunk calls dropped when (Feature 4) forwarded or tandemed
  through the BCM450.
  Q01910883, Q01926400

- An error popup while deconfiguring telephony resources
  Deconfiguring booted IP Trunks, booted IP Sets, or an MBM with booted
  sets or trunks would consistently result in a Deconfigure failure, try again
  error message to the user on the 1st request.  A Deconfigure request
  should now always work on the 1st attempt.
  Q01916706

- CALLING PARTY PRIVACY is not working
  Local BRI break out fails to honor Calling Party Privacy code from
  the CS1K main office. Presentation Restricted was set from CS1K MCDN,
  but not retained for the BRI call.
  Q01538245-04

- Hunt group IP phones intercom keys lock up
  The intercom keys get blocked only on the hunt group using ip
  phones but not the digital sets. The issue occurs on various ip phones
  on various times and on various hunt groups. The issue is; ip phone's intercom
  key gets locked up. Resetting ip phone or rebooting BCM resolves the issue.
  Q01870745-01

- TAT is not invoked for calls between BCM and CS1000E over SIP trunks
  When an answered call is transferred from the CS1000 back to the originating
  BCM, the TAT feature is not invoked when the call is answered on the BCM side.
  Q01839425-01

- Analog trunk locks up while parking
  Analog trunks lock up while using the call park feature.
  Line status shows "line in use."
  Q01860285-01

- Calls with NO CLID cannot connect to BCM via H323
  When incoming call from PSTN gets tandem out over VoIP trunk with private
  route, call gets dropped.
  Q01883856-02

- Failed to apply language via DN Template
  Set template uses "English" to represent North American English.
  This can be confused with English UK when setting up a template.
  Change to use the same language options as Voicemail; "English"
  changed to "English (North America)".
  Q01926898

- CLID through GATM8 does not work
  Caller Id is not working in UK profile for GATM. It applies to both GATM Ver1
  and GATM Ver2.
  Q01884757-02

- Calling Party Privacy is not working
  When a set dials using the ONN blocking feature (no calling party number
  provided), tandem node is not propagating the calling party presentation
  indicator to the end node.
  Q01538245-04

- The intercom keys on the IP phone in the hunt group get locked up
  A call coming in over a BRI/VOIP trunk gets answered by set A and
  set A transfers the call to HG01. HG members sets B, C and D ring. Once Set B
  answers the call, the intercom key of sets C and D remain lit and the sets C and D
  are locked up.
  Q01870745-01

- Software Update logs recorded password information in clear text
  SoftwareUpdateProviderAgent.log recorded a user id and password in cleartext
  when retrieving patches from remote locations. The fix is to no longer record
  this information in the log.
  Q01927648

- System interrupted when Element Manager queries "Active DNs"
  Pressing a TDM set key after the Active DNs update completes, results in slow
  response on the set.
  Q01928456


This update includes the content of the following superseded Smart Updates:

BCM450.R100.SU.System-003.200901